Main Features :
Excellent repeatability
Dead band adjustment for regulation
Fix dead band for control and alarm
Light weight
Explosion proof Hazardous areas 1, 2, 21, 22
Applications :
Power generation safety equipment
Water treatment
Valve and compressor control
Technical Data :
Temperature range -46 … 0 °C to 160 … 250 °C
Temperature Process : -46 … +250 °C
Ambient : -20 … +70 °C (T5)
-20 … +60 °C (T6)
Storage : -40 … +70 °C
Repeatability ± 1% F.S. / constant temperature cycle
CE conformity Low Voltage Directive 2014/35/EU
ATEX Directive 2014/34/EU
Protection rating IP 66 (EN 60529)
Process connection Stainless steel 1.4404 (316L)
Bulb Stainless steel 1.4404 (316L) bulb Ø 9.5 mm
Scale Internal graduated scale
Weight 2.00 kg + transmission
Housing Grey painted aluminum housing
Explosion proof
Mounting Wall mounting 2 x M6 x 16 screws
Ground connection Via internal or external terminal block
Electrical
connection
Via internal terminal block with cable gland
3/4 NPT certified ATEX/IECEx for Ø7 to 12 mm
cable
Electrical function See ordering code details page 5
Adjustment Internal adjustment possible for set point and
dead band
ATEX/IECEx Certificate
LCIE 02 ATEX 6219X
IECEx LCIE 15.0059X
Classification
II 2 G D
Ex d IIC T6 or T5 Gb
Ex tb IIIC T80 °C or T95 °C Db