Main Features:
Excellent repeatability
Dead band adjustment for regulation
Fix dead band for control and alarm
Resistant to accidental overpressure
Explosion proof Hazardous areas 1, 2, 21, 22
Applications:
Pneumatic appliances
Power generation safety equipment
Water treatment
Valve and compressor control
Technical Data :
Pressure range 0 … 1 bar to 0 … 100 bar
Temperature Process : -40 … +150 °C
Ambient : -20 … +70 °C (T5)
-20 … +60 °C (T6)
Storage : -40 … +70 °C
Repeatability ± 1% F.S. / constant pressure cycle
CE conformity Low Voltage Directive 2014/35/EU
ATEX Directive 2014/34/EU
Protection rating IP 66 (EN 60529)
Process Connection Stainless steel 1.4404 (316L)
Diaphragm Stainless steel 1.4404 (316L)
Scale Internal graduated scale
Weight 1.8 kg
Housing Grey painted aluminium housing
Explosion proof
Mounting 2 x M6 x 16 screws
Ground connection Via internal or external terminal block
Electrical
connection
Via internal terminal block with cable gland
3/4 NPT (ATEX/IECEx certified) for cable Ø 7 to 12
Electrical function See ordering code details on page 4
Adjustment Internal adjustment possible for set point and
dead band
ATEX/IECEx Certificate
LCIE 02 ATEX 6219X
IECEx LCIE 15.0059X
Classification
II 2 G D
Ex d IIC T6 or T5 Gb
Ex tb IIIC IIC T80 °C or T95 °C Db