Main Features:

Excellent repeatability
Fix dead band for control and alarm
Dead band adjustment for regulation
Explosion proof Hazardous areas 1, 2, 21, 22

Applications:

Power generation safety equipment
Presurized chambers control
Liquid level control

Categories: ,
Description

Technical Data :

Pressure range -50 mbar … 0 to 60 … 600 bar
Temperatures Pressure range codes 101 to 153
Medium: -15 … + 150 °C
Ambient: -20 … + 70 °C (T5)
-20 … + 60 °C (T6)
Storage: -40 … + 70 °C
Pressure range codes 200 to 602
Medium: -50 … + 200 °C
Ambient: -25 … + 60 °C (T6)
Storage: -40 … + 70 °C
Repeatability ± 1% F.S. / constant pressure cycle
CE conformity Low Voltage Directive 2014/35/EU
ATEX Directive 2014/34/EU
Protection rating IP 66 (EN 60529)
Process Connection Stainless steel 1.4404 (316L)
Sensing element Pressure range codes 101 to 153
Flanges: Stainless steel 1.4404 (316L)
Diaphragm: Viton®
Pressure range codes 200 to 209
Bellow: Stainless steel 1.4404 or
1.4432 (316L)
Pressure range codes 600 to 602
Piston: Nickel plated steel

Scale Internal. Accuracy on reading ± 5% F.S.
Housing Type RA80, explosion proof, flameproof
Alumunium epoxy painted.
Captive stainless steel screws
Mounting 3 back lugs for wall mounting
Ground connection Via internal terminal block
Electrical
connection
Terminal block with metallic cable gland for
Ø 7 to 12 mm standard
Electrical function See ordering code details in page 5
Adjustment 2 external adjustment screws on top of the case
for set point and dead band
ATEX/IECEx Certificate
LCIE 03 ATEX 6231X (Typ RA80)
IECEx LCIE 15.0061X
Classification
II 2 G D
Ex d IIC T6 oder T5 Gb
Ex tb IIIC IIC T80 °C oder T95 °C Db
T° ambient
-20 °C to +60 °C (T6 or T80 °C) or
-20 °C to +70 °C (T5 or T95 °C)