Selection Chart :
Ordering code DPx 100 / xxx.xxx
System design
Standard DPC
With liquid, glycerine 86% DPO
Nominal size
NG 100 100
Case
Stainless steel 1.4301, bright drawn, welded 8
Structural shape
Direct mounting 1
Upper flange
Ø 100 stainless steel 1.4301 3
Ø 150 stainless steel 1.4301 6
Scale
Standard 1
Measuring element
Duratherm 600* with Viton seal (E) 3
Duratherm 600* with PTFE coating 1) (P) 5
Lower flange
Male connection G½, stainless steel 1.4571 3
For further lower flanges see below 9
Technical Data :
Application For gaseous and liquid, also aggressive, low-viscosity media,
high overpressure safety, with open lower flange
also for high-viscosity media.
With fluid filling for measuring points subject to vibrations
and high dynamic pressure loads
Ambient temperature -20°C to +60°C
Media temperature Max 100°C
Temperature dependent < 0,8% / 10K
display error
Pressure range Flange ø 100 mm, 0.4 to 25 bar
Flange ø 150 mm, 60 to 250 mbar
Overpressure safety Flange ø 100 mm, 400 mbar, 2.5 x
(with ordering code 0201) Flange ø 100 mm, from 0.6 bar, 5 x, max. 40 bar
Flange ø 150 mm, 10 x
Range of application For static pressure 100% of full scale
For dynamic pressure 90% of full scale
Accuracy Cl. 1,6 according to DIN EN 837-3
Execution DIN EN 837-3
Movement Stainless steel
Dial White, black scale acc. EN 837-3
Pointer Aluminium, black, DIN EN 837-3
Window Multilaminated safety glass
Case Welded, with blow-out lid, back (S1 acc. DIN EN 837-3)
Protection IP 65 acc. EN 60529 / IEC 529
higher protection class possible as an option (see overleaf)